Upstream and downstream handoff
Use arrows to show part flow and upstream discharge and downstream pickup points. Give conveyor heights and adjustment ranges. Allow room for roll replacement. For tray loading, mark the empty-tray infeed and full-tray removal sides.
Power, air and wiring
Mark site voltage, frequency, distribution and earthing points. For pneumatics or vacuum, provide pressure ranges and conditions at the point of use. Confirm connection details, air consumption and line lengths for the selected configuration.
Cycle timing and handoff signals
Define who sends ready, in-position and cycle-complete signals. Record sender, receiver, reset conditions and timeout handling, and agree on how upstream feeding pauses when a tray is full or parts are unavailable.
Sample testing and site handover
For labeling, inspect offset and appearance. For tray loading, check orientation, empty pockets and damage. Mark measurement datums on samples, agree on batches, timing and material changes, and keep approved sample photos and measurements for site comparison.